ORA-01083: value of parameter “string” is inconsistent with that of other instances ORACLE 报错 故障修复 远程处理

文档解释

ORA-01083: value of parameter “string” is inconsistent with that of other instances

Cause: The value of the given parameter is required to be the same for all instances in the cluster database configuration. ROW_LOCKING and SERIALIZABLE are 2 examples.

Action: Change the value of the parameter in INIT.ORA file to match that of other cluster database instances.

ORA-01083错误指示当前参数值与Oracle数据库其他实例之间的设置出现不一致。

官方解释

ORA-01083:value of parameter “string” is inconsistent with that of other instances

Cause:The value of the given initialization parameter is not the same on all instances of the database.

Action:Make sure that all instances of the database have the same value for the parameter specified in the message.

常见案例

ORA-01083错误可能是由RAC(Real Application Clusters)数据库配置时误用为同一初始化参数对不同实例设置了不同值引起的,或者在运行时通过修改一个初始化参数而使得其他实例不能使用同样的修改值引起的。

正常处理方法及步骤

1. 检查当前的环境,检查是否存在ORA-01083错误。

2. 使用V$PARAMETER查看初始化参数是否有不一致的设置情况,如果是,需要进行检查何处出现的不一致的情况。

3. 对给出的初始化参数,使用“ALTER SYSTEM”语句在所有实例上设置相同的值。

4. 永久更改所有实例参数值,则需要记录修改记录,并保存在“init.ora”文件中。